当前位置:首页 > 报告详情

英特尔服务器设计战略创新:提升 19 英寸高密度机架式服务器的兼容性和性能.pdf

上传人: 明**** 编号:1011538 2025-12-21 16页 1.05MB

1、Strategic Innovations in Intel Server Design:Strategic Innovations in Intel Server Design:Enhancing Compatibility and Performance inEnhancing Compatibility and Performance in19 inches High Density Rack Server19 inches High Density Rack ServerIntelStrategic Innovations in Intel Server Design:Enhancin

2、g Compatibility and Performance in19 inches High Density Rack ServerSERVERAnn Yen,Thonas SuIntelAgenda Preface-Impossible or Im Possible Layout Example Via Placement Suggestion and Crosstalk Simulation Result DDR5 Channel Simulation ResultPreface-Impossible or Im PossibleBackgroundBackground Dimensi

3、ons of the processor increases Dual processors 2 SPC(slot per channel)configuration is not possible to fit into 19”RACK Dual processors 1 SPC configuration under traditional DIMM connector placement cannot fit into 19”RACKSolutionSolution Reduce DIMM pitch(values varies among designs)Shrink CPU keep

4、 out zone Adapt DIMM connector which can compliance with narrow DIMM pitch Adapt Via in Pad Plated Over(VIPPO)in DIMM connectorDIMM1DIMM0CPUDIMM1DIMM02 Slots per ChannelDesignDIMM0DIMM0CPUDIMM0DIMM0CPU1Slot per ChannelDesignDIMM Pitch ReductionVIPPO and Pitch ReductionPhysicalLimitation5Intel Confid

5、entialRevision:X.XReference Number:XXXXXXLayout ExampleDIMM0DIMM0CPUDIMM0DIMM0CPUDIMM Pitch(DIMM to DIMM)32X milDIMM Pitch(DIMM to DIMM)26X milNarrow DIMM Pitch and VIPPO Layout ExampleNote:Note:VIPPO stands for Via in Pad Plated OverNon VIPPO,DIMM Pitch=32X milVIPPO,DIMM Pitch=32X milVIPPO,DIMM Pit

6、ch 26X mil7Intel ConfidentialRevision:X.XReference Number:XXXXXXDIMM to DIMM Via Placement Suggestion and Crosstalk Simulation Result CH6 CH7CH0 CH1 CH2 CH3CH4 CH5CH_6CH_6CH_7CH_7P5P5P15P15P30P30Layout and Port ViaPort 30Port 5CH_NCH_NCH_N+1CH_N+1Port 15Via Placement Suggestion(1 of 2)FarFar-End Cro

word格式文档无特别注明外均可编辑修改,预览文件经过压缩,下载原文更清晰!
三个皮匠报告文库所有资源均是客户上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作商用。
根据《Strategic Innovations in Intel Server Design: Enhancing Compatibility and Performance in 19 inches High Density Rack Server》的内容,以下是全文关键点的概括: 1. **设计挑战**:随着处理器尺寸增加,传统的双处理器配置在19英寸机架服务器中无法容纳。 2. **解决方案**:通过减小DIMM间距、缩小CPU保持区域、采用窄间距DIMM连接器和“Via in Pad Plated Over”(VIPPO)技术来解决空间限制。 3. **布局示例**:展示了采用VIPPO和窄DIMM间距的布局示例。 4. **信号完整性**:通过模拟和实验,分析了DIMM间串扰和最短通道的反射风险,评估了设计风险。 5. **模拟结果**:对于DDR5通道,只有当通道违反平台设计指南(PDG)时,客户才需要进行模拟。 6. **测试计划**:计划在电源开启后进行DDR5眼高测试和稳定性测试。 核心数据包括: - VIPPO技术使DIMM间距从32X mil减少到约26X mil。 - 串扰模拟显示,参考板在DIMM到DIMM的串扰方面优于研究案例1(D2D=0.26X”,约-16 dB)。